Find the frequency, duty cycle and on/off times of an NE555 in astable mode from R1, R2 and C.
Formulas (astable mode)
t_high = 0.693 × (R1 + R2) × Ct_low = 0.693 × R2 × Cf = 1.44 / ((R1 + 2·R2) × C)
Notes
- Duty cycle is always above 50% in the basic circuit. Add a diode across R2 to get below 50%.
- Keep R1 above about 1 kΩ so the discharge transistor is not overloaded.
- Electrolytic capacitor tolerance (±20%) is usually the biggest source of timing error.
More calculators
- PCB Trace Width Calculator (IPC-2221)
- Voltage Divider and ADC Scaling Calculator
- LED Series Resistor Calculator
- Battery Backup Time Calculator for Inverters and UPS
- CT Burden Resistor Calculator for Microcontroller ADC
- Ohm’s Law and Power Calculator
- Resistor Colour Code Calculator (4 and 5 Band)
- RC Time Constant and Cut-off Frequency Calculator
- IPS / Inverter Size and Battery Calculator for Home
- Electricity Unit (kWh) and Bill Calculator
- Solar Home System Size Calculator (Panels, Battery, Controller)
Need this designed for your product? We design power electronics, embedded firmware and industrial IoT hardware. Message us on WhatsApp or use the contact form.