Planning an IPS for load-shedding? Add your fans, lights and other loads to estimate the IPS rating (VA) and the battery capacity you need.
| Load | Watts each | Quantity |
|---|
How the estimate works
- IPS rating (VA) = total watts ÷ 0.7 (typical power factor of home loads) × 1.25 (margin for motor start-up and future loads).
- Battery Ah = watts × hours ÷ (battery voltage × 0.85 inverter efficiency × usable depth of discharge).
- Lead-acid and tubular batteries last longer if you only use about half their capacity. LiFePO4 batteries can safely use about 80%.
Practical tips
- Fans with BLDC motors use 30–35 W instead of about 75 W, nearly doubling your backup time.
- Avoid running refrigerators, irons, rice cookers or water heaters on a small IPS.
- A pure sine wave IPS is quieter for fans and safer for electronics.
Want to know how a sine wave inverter works inside? See our pure sine wave inverter tutorial.
More calculators
- PCB Trace Width Calculator (IPC-2221)
- Voltage Divider and ADC Scaling Calculator
- LED Series Resistor Calculator
- Battery Backup Time Calculator for Inverters and UPS
- CT Burden Resistor Calculator for Microcontroller ADC
- Ohm’s Law and Power Calculator
- Resistor Colour Code Calculator (4 and 5 Band)
- 555 Timer Astable Calculator
- RC Time Constant and Cut-off Frequency Calculator
- Electricity Unit (kWh) and Bill Calculator
Need this designed for your product? We design power electronics, embedded firmware and industrial IoT hardware. Message us on WhatsApp or use the contact form.