Find the minimum copper width for a PCB trace from its current, copper weight and allowed temperature rise. The calculator uses the IPC-2221 curve fit and also estimates the trace resistance, voltage drop and power loss for a given length.
How it works
IPC-2221 relates the required copper cross-section to current and temperature rise:
A = ( I / (k × ΔT0.44) )1/0.725
where A is the cross-sectional area in mil², I the current in amperes, ΔT the temperature rise in °C, and k = 0.048 for outer layers or 0.024 for inner layers. The width is A divided by the copper thickness (1 oz/ft² ≈ 1.378 mil ≈ 35 µm).
Design notes
- IPC-2221 is conservative for wide traces and was fitted for currents up to about 35 A. For high-current power stages, check IPC-2152 or use copper pours, busbars or wire.
- Inner layers dissipate heat worse than outer layers, so they need roughly twice the cross-section for the same rise.
- Keep high-current loops short: resistance and inductance both grow with length.
- Add margin for production tolerance: fabricators can etch traces 10–20% narrower than drawn.
More calculators
- Voltage Divider and ADC Scaling Calculator
- LED Series Resistor Calculator
- Battery Backup Time Calculator for Inverters and UPS
- CT Burden Resistor Calculator for Microcontroller ADC
Need this designed for your product? We design power electronics, embedded firmware and industrial IoT hardware. Message us on WhatsApp or use the contact form.