Load-shedding is part of life in many parts of Bangladesh, and an IPS (instant power supply) is the most common way to keep fans, lights and the Wi-Fi router running. Buying the wrong size, however, means short backup, a battery that dies early, or an inverter that trips when the fan starts. This guide explains how to choose an IPS that fits your home, in plain language.
- How an IPS works
- Step 1: add up your loads
- Step 2: choose the IPS rating (VA)
- Step 3: choose the battery
- Sine wave or square wave?
- Installation and safety tips
- FAQ
Table of Contents
How an IPS works
Step 1: add up your loads
List only what you really need during load-shedding. Typical power ratings:
| Appliance | Typical power | Notes |
|---|---|---|
| Ceiling fan (regular) | 60–80 W | The biggest load in most homes |
| Ceiling fan (BLDC) | 28–35 W | Halves fan consumption |
| LED bulb | 5–15 W | |
| LED tube light | 18–22 W | |
| LED TV 32–43 inch | 40–80 W | |
| Wi-Fi router + ONU | 10–20 W | Small but always on |
| Laptop charging | 45–90 W | |
| Refrigerator | 100–200 W running | High starting current; needs a large IPS |
Example: 3 fans (75 W) + 6 LED bulbs (10 W) + 1 TV (60 W) + router (15 W) = 360 W.
Step 2: choose the IPS rating (VA)
IPS units are sold in VA, not watts. Home loads have a power factor below 1, and motors (fans, pumps) draw extra current when they start, so size with margin:
IPS VA ≈ total watts ÷ 0.7 × 1.25
For 360 W that is about 640 VA, so a 650–800 VA IPS is the right choice. Our IPS size calculator does this for you.
Step 3: choose the battery
Backup time depends on the battery, not the IPS. Use:
Battery Ah ≈ watts × hours ÷ (battery voltage × 0.85 × usable fraction)
| Battery type | Usable capacity | Life | Notes |
|---|---|---|---|
| Tubular lead-acid | about 50% | 4–6 years with care | Most common; needs distilled water top-up |
| Sealed (SMF/VRLA) | about 50% | 2–4 years | No maintenance, shorter life in heat |
| LiFePO4 lithium | about 80–90% | 8–10+ years | Higher price, much lighter, needs a compatible charger |
Example: 360 W for 3 hours on a 24 V system with tubular batteries needs about 360 × 3 ÷ (24 × 0.85 × 0.5) ≈ 106 Ah, so two 12 V 100–120 Ah batteries in series. Check different options with the battery backup time calculator.
Sine wave or square wave?
- Pure sine wave IPS units give clean power: fans run quietly and cool, and electronics such as TVs, routers and laptop chargers are safe.
- Modified/square wave units are cheaper but make fans hum and run warmer, and some chargers and LED drivers fail early.
- For a new purchase, a pure sine wave IPS is worth the small extra cost.
Curious what is inside a sine wave inverter? See our PIC16F76 pure sine wave inverter tutorial.
Installation and safety tips
- Keep the battery in a ventilated place; lead-acid batteries release hydrogen while charging.
- Use thick enough battery cables and tight lugs; loose connections cause heat and voltage drop.
- Have the changeover wiring done by an electrician so the IPS output never feeds back into the grid.
- Do not connect irons, heaters, rice cookers or water pumps to a small IPS.
- Check tubular battery water level every 1–2 months.
FAQ
Can an IPS run my refrigerator?
Only a large, pure sine wave IPS (usually 1,500 VA or more) with a big battery. The compressor start current is several times its running power.
Why does my backup time fall every year?
Lead-acid batteries lose capacity with age, deep discharge and heat. Keep them topped up and avoid draining them completely.
Need an IPS, inverter or charger designed for your product or factory? Message us on WhatsApp or use the contact form. You can write in Bangla or English.