Enter the code printed on a ceramic or film capacitor to get its value in pF, nF and µF, plus the tolerance letter.

Reading capacitor codes

Small ceramic and film capacitors use a 3-digit code in picofarads: the first two digits are the value and the third is the number of zeros. 104 = 10 × 10⁴ pF = 100,000 pF = 100 nF = 0.1 µF, the most common decoupling capacitor. 103 = 10 nF, 222 = 2.2 nF, and two-digit codes such as 22 mean 22 pF.

A letter after the code is the tolerance: J = ±5%, K = ±10%, M = ±20%. The voltage rating is printed separately (for example 50V or 2A = 100 V on some film caps).