Enter your buck converter specs to get duty cycle, inductor value, peak switch current and output capacitance for your ripple target.

Formulas used (ideal, continuous mode)

  • D = Vout / Vin (real converters need slightly more because of losses).
  • L = (Vin − Vout) × D / (fsw × ΔI), with ΔI chosen as 20–40% of output current.
  • Ipeak = Iout + ΔI/2: pick an inductor whose saturation current is comfortably above this.
  • Cout ≈ ΔI / (8 × fsw × ΔV) for the capacitive part of the ripple; ESR adds ΔI × ESR on top.

Building one? Read our buck converter with a low-side MOSFET and the MPPT synchronous buck guide.